Home UAE BMS Operator - DC

Home UAE BMS Operator - DC

BMS Operator - DC

Full time at ENGIE Group in UAE
Posted on November 3, 2024

Job details

The Data Center Facilities BMS/DCIM Operator is responsible for supervising and controlling the operation of the building management system (BMS) & Data Center Infrastructure Management (DCIM) System. This includes monitoring all Electrical, ELV, and fire/life safety equipment, as well as HVAC plant activities to ensure the Data Center building services operate at peak efficiency. The Operator serves as an expert technical resource, reporting and interacting with onsite Engineers and third-party vendors, ensuring data center equipment that supports mission-critical servers maintains better than 99.999% uptime.

Key Responsibilities:

  1. Operate and maintain the Building Management System (BMS) for proper function and monitor the DCIM against approved benchmarks, including HVAC, Lighting, Fire Suppression, Generator, Plumbing, and Electrical.
  2. Carry out routine checks for the correct operation of all control equipment as directed by the Facility Engineer.
  3. Monitor the operation of the HVAC control systems using the BMS/DCIM to ensure performance.
  4. Adjust variables and provide adjustments as required to ensure systems operate correctly within parameters.
  5. Monitor and record values of HVAC systems to build a database for energy efficiency improvement.
  6. Communicate all maintenance and repair actions in writing to management as required.
  7. Follow protocols for unexpected technical difficulties and other problems that may arise.
  8. Monitor and verify the operation of all BMS/DCIM field devices.
  9. Adjust BMS settings and parameters to meet changing conditions (e.g., Load, Environmental, Customer needs).
  10. Record maintenance data and generate reports as needed.
  11. Maintain job card documentation for all alarms or changes to systems and/or equipment.
  12. Monitor fire detection alarm systems, including smoke detectors, heat detectors, sprinklers, and emergency exits, in coordination with the Safety Function.
  13. Monitor water tank supply level alarms and air handling units.
  14. Monitor and control the Fire pump system, motors, sewage pump, electrical system, and water system in the Data Center building.
  15. Perform miscellaneous tasks as assigned by the Facility Engineer.
  16. Check the healthiness of all facilities equipment daily and keep daily logs and records of all maintenance functions.
  17. Create job cards in the CAFM (FSI) Mobile App as per site requirements and close the job cards assigned by the Engineer.
  18. Respond promptly and efficiently to emergency calls.
  19. Review and understand equipment and methods of operation, including Electrical systems, ELV systems, fire/life safety, and other systems.
  20. Comply with all safety procedures and requirements.
  21. Support any after-hours building needs and activities as required.
  22. Attend training sessions and seminars.
  23. Perform other assigned tasks as requested.

Skills Required:

  1. Working knowledge of Electrical & ELV systems, including secondary distribution and HVAC interior systems.
  2. Ability to read CAD Drawings, single-line diagrams, and rough shop drawings.
  3. Strong knowledge in multiple skilled trades (electrical, HVAC, plumbing, etc.).
  4. Ability to analyze the operation of various infrastructure systems, determine the cause of problems/malfunctions, and take corrective actions.
  5. Trained and experienced in BMS/DCIM operation.
  6. Vigilant with attention to detail.
  7. Ability to handle emergency situations calmly.
  8. Integrity, commitment, and courtesy.
  9. Following instructions & procedures.

Personal Skills:

  1. Good English communication skills are required.
  2. Good working knowledge of PC systems and CAFM Mobile Apps.
  3. Persistent and self-motivated.
  4. Excellent organizational skills and initiative to learn and take on new responsibilities.
  5. Ability to work in a fast-paced environment with minimal supervision.
  6. Good problem-solving skills and ability to meet demanding time constraints.
  7. Self-motivated and independent.
  8. Excels in ambiguous situations as a chance to show leadership.
  9. Strong team player with the ability to influence, develop, and maintain relationships with internal/external contacts.
  10. Articulate, friendly, and diplomatic with the ability to negotiate.

Qualifications:

2-3 years BMS/DCIM Operator experience in Data Center Maintenance/Operations. 5+ years total experience in BMS/DCIM.

Other Requirements:

DC certifications will be an added advantage. Experience in Microsoft Applications (Office, Excel, Word, Outlook).

Business Unit:

GBU Energy Solutions

Division:

ESI AMEA - GCC & Pak - UAE

Legal Entity:

ENGIE Cofely Energy Services LLC

Contract Type:

Permanent

Job Type:

Full-Time

Professional Experience:

Skilled (>3 years <15 years)

Education Level:

Technical College Diploma #J-18808-Ljbffr

Apply safely

To stay safe in your job search, information on common scams and to get free expert advice, we recommend that you visit SAFERjobs, a non-profit, joint industry and law enforcement organization working to combat job scams.

Share this job
See All BMS Jobs
Feedback Feedback