Annual Maintenance Contract (AMC) for Water Testing & Treatment Services
Description
AMC for Water Testing & Treatment – La Riviera Tower, Dubai Marina The objective of this Annual Maintenance Contract (AMC) is to ensure the effective treatment, testing, and management of the water systems at La Riviera Tower, Dubai Marina, in compliance with Dubai Municipality, DEWA, and international water safety standards. Asset Description: Domestic Water Circuit: 1 No. Swimming Pool Circuit: 1 No. Chilled Water Closed Circuit: 1 No. Water Feature Circuit: 1 No. Service Frequency & Testing Requirements: A. Domestic Water Circuit: Sampling Points: 4 points (Water Tanks and Random Outlets) Frequency: Quarterly Tests: Microbiological (TBC, E.Coli, Coliforms), Legionella, Full Chemical Analysis (p H, chlorine, TDS, hardness, alkalinity, turbidity) B. Swimming Pool Circuit: Sampling Point: 1 point (Swimming Pool) Frequency: Legionella - Quarterly, Microbiological - Bi-monthly, Chemical Analysis - Bi-weekly Tests: Free chlorine, p H, cyanuric acid, calcium hardness, total alkalinity, saturation index C. Chilled Water Circuit: Sampling Point: 1 point (Closed Loop) Frequency: Quarterly Tests: Microbiological (TBC, Pseudomonas), Legionella, Full Chemical Analysis (Nitrite, p H, TDS, Iron, corrosion inhibitor levels) D. Water Feature Circuit: Sampling Points: 3 points Frequency: Quarterly Tests: Microbiological (TBC), Legionella, Full Chemical Analysis (Chlorine, p H, TDS, hardness) Service Frequency: Domestic Water Circuit: Samples: 4 (every test) Locations: Water tanks and outlets Legionella Test: Every 3 months Microbiological Test: Every 3 months Swimming Pool Circuit: Samples: 1 (every test) Location: Swimming Pool Legionella Test: Every 3 months Microbiological Test: Every 2 months Consumables and Spare Parts: Comprehensive PPM consumables included in the service Scope of Work: Sampling Arrange samples from locations advised by the client Provide sampling containers and transportation to laboratory Analysis and Reporting Conduct tests per international standards Report details include: Name, address, location, report number, sample ID, sampling date/time/place, description, receipt date, report date, transportation method, sampling method, test method, result units, results, remarks/recommendations Electronic results delivered within 7 days (Microbiology) and 15 days (Legionella) Original certificate delivered to site in the same month of sampling Safety Policy: Provide safety gear (uniform, gloves, masks) Isolate work area with partitions and signage Clean area after work, remove tools and waste Vendor responsible for employee safety and liabilities #J-18808-Ljbffr
Posted: 27th June 2025 7.55 am
Application Deadline: N/A
Similar Jobs
Explore more opportunities like this