Fire Alarm Mass Notice Technician Vectrus
Detalhes do emprego
Job title: Fire Alarm Mass Notice Technician
Company: Vectrus
Job description: Job Description:OverviewWorking across the globe, V2X builds smart solutions designed to integrate physical and digital infrastructure from base to battlefield. We bring 120 years of successful mission support to improve security, streamline logistics, and enhance readiness. Aligned around a shared purpose, our $3.9B company and 16,000 people work alongside our clients, here and abroad, to tackle their most complex challenges with integrity, respect, responsibility, and professionalism.Responsible for operation, maintenance and repair of fire alarms, mass notification, fire suppression systems to include ANSUL wet chemical systems, backflow prevention, fire hydrant flow testing and marking per NFPA standards in support of base operations. Reports to the Fire Alarm Technician Lead and works with a team of OM&R Fire Alarm, Suppression, Mass Notification, Fire Hydrants & Backflow Prevention Systems Professionals.ResponsibilitiesMajor Responsibilities:
Shall inspect, test, maintain, repair, and replace fire alarm systems and mass notification systems (MNS) basewide, to include Fire Department control systems, in a manner that will ensure their serviceability and operation IAW applicable standards and manufacturer's instructions.
Shall perform functional operation tests on installed fire detection and alarm systems to ensure that fire alarm systems are operational IAW applicable Unified Facility Codes (UFC), NFPA Standards and manufacturer's instructions.
Interpret instruments and meter readings, use wiring diagrams, schematics, drawings and technical publications, use applicable test equipment, enforce safety rules and practices, environmental policies, and principles of management and operation of on-site fire alarm and control systems.
Shall review the design to ensure that all NFPA Standards and building construction specifications are met to include applicable National Fire Protection Administration (NFPA) and Unified Facilities Criteria (UFC).
Follow preventative maintenance plan and maintain records.
Responsible for following and implementing work prioritization requirements within provided timelines using automated management systems for all work orders.
Responsible for following a comprehensive safety program in compliance with Vectrus, OSHA and United States Air Force (USAF) requirements.
Responsible for maintaining a safe, clean, sanitary, healthy, presentable, professional atmosphere, free of dust, clutter and trash in all working facilities and areas.
Responsible for following a comprehensive, flexible, and properly documented training program.
Responsible for proper utilization and safeguarding of all government and contractor provided property (e.g., to include government facilities, equipment and tools).
Responsible for precise execution of company time reporting procedures and accurate completion of timesheet.
Perform other duties as assigned in accordance with contractual, functional, and mission requirements
Other requirements:
Work will be primarily indoors but may be outdoors to support various events.
Exposure to heat, cold, dust, noise, chemicals may occur.
Overtime and shift work may be required depending on contractual needs.
Employee must comply with all Federal, State and Local regulations and published Company work rules as well as written instructions.
Task specific work environment training will be provided as required.
Must be prepared to function in a wartime environment to support U. S. interests.
100% Overseas Assignment.
QualificationsMinimum Qualification:Education/Certifications: One year related experience may be substituted for one year of education, if degree is required.
Mass Notification Technicians shall meet the qualifications required by UFC 4-021-01.
Fire Alarm Technicians shall be NICET Level I Certified and have direct experience relating to the installation, maintenance, and
testing of fire alarm systems.
Must have a current, valid U. S. Passport and Driver's License (able to drive manual transmission).
Must have and maintain a valid U. S. SECRET Security Clearance prior to deployment.
Must obtain an Air Force flight line driver's license upon deployment.
Must pass a flight line access test and obtain flight line access badge upon deployment.
Must be able to pass employment and deployment qualification requirements that include psychological, medical, dental, drug
testing and background checks.
Candidates must successfully complete both online and hands-on CBRN (chemical, biological, radiological and nuclear) defense
training. Training includes the successful fit testing of DOD provided protective gear.
Experience:
Direct experience relating to the management of fire alarm mass notification and suppression system maintenance and testing.
Shall be experienced in implementation and compliance with UFC 4-021-01, Design and O&M Mass Notification Systems
Preferred knowledge of UFC 3-601-02, Operations and Maintenance: Inspection, Testing, and Maintenance of Fire Protection System
We are committed to an inclusive and diverse workplace that values and supports the contributions of each individual. This commitment along with our common Vision and Values of Integrity, Respect, and Responsibility, allows us to leverage differences, encourage innovation and expand our success in the global marketplace. V2X is an Equal Opportunity /Affirmative Action Employer. All qualified applicants will receive consideration for employment without regard to race, color, religion, age, sex, national origin, protected veteran status or status as an individual with a disability. EOE/Minority/Female/Disabled/Veteran.
Expected salary:
Location: Qatar
Job posting date: Fri, 17 May 2024 22:05:59 GMT
Apply for the job now!
#J-18808-Ljbffr Assistance
Apply safely
To stay safe in your job search, information on common scams and to get free expert advice, we recommend that you visit SAFERjobs, a non-profit, joint industry and law enforcement organization working to combat job scams.